Product Details:
Payment & Shipping Terms:
|
Production Capacity: | 180-2000 M3/hour | Power: | 200-2000 KW |
---|---|---|---|
Voltage: | 380v,6000V,10000V | LO2 Purity: | 99.6% |
LOX Pressure: | 0.08 MPA | LO2 Flow: | 100, 200, 300, 500, 1000L/h |
Product Name: | Liquid Oxygen Plant | ||
High Light: | Industrial Oxygen Generator,Oxygen Production Plant |
80m3/h-1000 m3/hour Industrial Liquid Oxygen Plant , Air Separation Unit
Quick Details:
Condition: new
Place of origin: China(mainland)
Brand name: UIG
Model number: KDO, KDON, SERIES
Production capacity:180-2000 m3/hour
Power :200-2000 KW
Voltage:380v,6000V,10000V
Certification: ISO 9001:2000
Warranty:1 year
Life:20 years with proper maintenance
After-sales service provided: Engineers available to service plants overseas
Usage: Industrial and medical (oxygen, liquid oxygen)
UIG Air separation plants are designed for a vast range of capacities and products summarized below: FOR OXYGEN 99.7 % AND NITROGEN 99.999%
Specifications:
LO2 flow |
100 L/h |
200 L/h |
300 L/h |
500 L/h |
800 L/h |
LO2 purity |
99.6% |
99.6% |
99.6% |
99.6% |
99.6% |
LOX pressure |
0.08 MPA |
0.08 MPA |
0.08 MPA |
0.08 MPA |
0.08 MPA |
LN2 flow |
(100 L/h ) |
(200 L/h ) |
(300 L/h ) |
(500 L/h ) |
(800 L/h ) |
LN2 purity |
99.999% |
99.999% |
99.999% |
99.999% |
99.999% |
LN2 pressure |
0.08 MPA |
0.08 MPA |
0.08 MPA |
0.08 MPA |
0.08 MPA |
Start-up time |
5-8 Hours |
5-8 Hours |
5-8 Hours |
5-8 Hours |
5-8 Hours |
Operating period |
≥2 Years |
≥2 Years |
≥2 Years |
≥2 Years |
≥2 Years |
Process:
Air→ Air compressor → Pre-cooler → Purifier →Rectification column and Turbo-expander →liquid oxygen tank or liquid nitrogen tank
Description:
Air enters the suction air filter and after being removed of dust and other mechanical contaminants in it, it is compressed to the pressure of 1.0MPa by air compressor. Air from the air compressor is cooled to 10℃ in the air precooling system and separated condensing water in water separator. after the water being separated its condensed water, taken into the molecular sieve adsorber for removing H2O, C2H2 and CO2.
Then the cleaned air is divided into two streams, one of them is taken into the rectifying column and cooled by the return waste nitrogen, oxygen,expander air through the main heat exchanger. The steam-liquid air mixture is taken into the lower column for rectifying, and herein the pure nitrogen from the top of the column enters into the evaporator-condenser and condensed by liquid oxygen from the upper column. A part of the liquid nitrogen is fed to the lower column as reflux. The other part after subcooling apart two parts after throttled. One part enters into the top of the upper column,other part enters storage tank as product(LIN).
Another cleaned stream is compressed in booster end of the booster expansion turbine, then enters the main heat exchanger. air from the middle and cold end of the main heat exchanger enter into the turbine expansion to generate most refrigeration for need of the plant's operation. After the expanded air return to heat exchange.
The LOX is drawn from oxygen side of the evaporator-condenser, some of them enters storage tank as product.
To meet different demands from customers, different processes like air cycle process ,nitrogen cycle process, high and low temperature booster turbine expanding processor low temperature refrigerating process etc. are adopted to reduce the power consumption. In order to achieve stable and reliable operating of plant, PLC control system or DCS control system are recommended.
Applications:
We have supplied to many countries (Russia, Kazakhstan, Tajikistan, India, Bangladesh, Thailand, Philippines, North Korea, Mongolia, Equatorial Guinea, Botswana, Zambia, Angola, Tanzania) .
Competitive Advantage:
1. All unit machines are skid-mounted construction, connected by fixed-size short pipe, after testing on supplier site, delivery the plant together with all pipes and valve to User site, the User needn't buy them by themselves, we make ensure the plant's perfect and integrate.
2 The User only need prepare well the workshop, workshop ground and crane is ok, needn't prepare other installation materials and tools.
3 Small volume, occupied small area
4 Complete set of plant be installed without foundation, also has following advantages: Stable running, easy operation, convenient maintenance, without easy-damaged spare parts within two years.
5 To keep all valve's quality, the cold-valve of Rectification column adopt the best-quality valve in Air separation Industry; The Purifier valve adopt stainless steel valve, install thermostability mat in it, ensure little wear, no cooling leak, no gas leak, long life, during the long-term running.
6 All unit machines adopt the advanced technology, so reduce power consumption greatly, save electricity fee.
7 The cooling way of plant is by air, the User needn't make cooling water pool, save capital cost.
8 The installation and commissioning time is very short, it only need 5-10 days.
Tag: Steel oxygen plant,Industrial oxygen plant,Steel liquid oxygen plant,Oxygen plant,Steel oxygen gas plant,Liquid oxygen plant
Contact Person: Alice
Tel: +8613735413366